The G353A049 sits between the compressed air header and the blowpipe in a pulse jet dust collector. The threaded angle body routes the cleaning air toward the blowpipe, while a separate pilot controls when the main valve opens.
| Feature | G353A049 |
|---|---|
| Main pipe connections | G2½ threaded |
| Remote pilot connection | G¼ |
| Main orifice | 66 mm |
| Flow coefficient | Kv 92 m³/h |
| Body | Aluminum |
| Valve function | 2/2 normally closed, dual stage |
On a cleaning command, the external pilot vents the control circuit. The first stage relieves pressure above the main diaphragm, allowing the main passage to open and send a short burst through the blowpipe. After the pilot closes, pressure rebuilds and the valve seals between pulses.
The controller wires connect to the separate pilot solenoid. A pneumatic line links that pilot to the bonnet of the G353A049.
It is the diameter of the main orifice. The G2½ designation specifies the pipe thread.
A panel can house the separate pilot valves for multiple cleaning lines. Each pilot has its own control line to the corresponding main pulse valve.